當(dāng)前位置:Anhui Xin Huan Neng Electrical Co., LTD.>>Instruments and Apparatuses>>Pressure / differential pressu>> 3051 h type high temperature pressure transmitter (rosemount

3051 h type high temperature pressure transmitter (rosemount

產(chǎn)品二維碼
參  考  價(jià):面議
具體成交價(jià)以合同協(xié)議為準(zhǔn)
  • 產(chǎn)品型號(hào):
  • 品牌:
  • 產(chǎn)品類別:其他
  • 所在地:
  • 信息完整度:
  • 樣本:
  • 更新時(shí)間:2024-09-12 13:46:33
  • 瀏覽次數(shù):22
收藏
舉報(bào)

聯(lián)系我時(shí),請(qǐng)告知來(lái)自 歐亞貿(mào)易網(wǎng)

Anhui Xin Huan Neng Electrical Co., LTD.

其他

  • 經(jīng)營(yíng)模式:其他
  • 商鋪產(chǎn)品:431條
  • 所在地區(qū):
  • 注冊(cè)時(shí)間:2024-09-12
  • 最近登錄:2024-09-12
  • 聯(lián)系人:manager Lu
  • 電    話:18019898888

產(chǎn)品簡(jiǎn)介

Productdescription:Technicalparameters:Measurableprocesstemperatureupto375°F(191°C),anddonotneedtousethediaphragmsealandcapillarywaterAccuracyis0

詳情介紹

Product description:

Technical parameters:
Measurable process temperature up to 375 ° F (191 ° C), and do not need to use the diaphragm seal and capillary water
Accuracy is 0.25%, the range than 100:1
Under the high temperature applications, temperature and time response
The sensing film head and circuit board is the same as the type 3051 c

model
Transmitter type (choose one)
TY3051HD
TY3051HG
Differential pressure transmitter, used for high temperature process
Gauge pressure transmitter, used for high temperature process
code
Pressure range (URL) (a)
2
3
4
5
0-2.5 and 0-250 inh2o (0-0.62 to 0-62.2 kPa)
0-10 to 0-1000 inH2O (0-2.48 and 0-248 kpa)
0-3 to 0-300 psig (0-20.7 and 0-2070 kpa)
0-20 to 0-2000 psig (0-138 to 0-13800 kpa)
code
The output
A
M(1)
4-20 ma, with digital signal based on HART protocol
1-5 Vdc, low power consumption, with a digital signal based on HART protocol (0.8-3.2 Vdc output, with the option code C2)
code
Process connectionProcess flange materialDrainage/exhaustFlange joint
2
7 (2)
SSTSSTSSTHartz alloySSTSST
code
Process isolation diaphragm
2
3 (2)
5
316L SST
Hartz alloy C - 276
tantalum
code
O-rings material
A
Glass filled tetrafluoroethylene (TFE)
code
Process of charging
D
H
N
200 silicone d.c.
Inert liquid
Neobee M-20
code
Sensing film head isolation diaphragm material
2
SST
code
Sensing head liquid membrane
1
2
Silicone oil
Inert liquid (halogenated hydrocarbon)
code
The shell materialConduit entrance size
A
B
C
D
J
K
L
Aluminum, polyurethane coatingAluminum, polyurethane coatingAluminum, polyurethane coatingAluminum, polyurethane coatingSSTSSTSST1/2-14NPTM20×1.5(CM20)PG13.5G1/21/2-14NPTM20×1.5(CM20)PG13.5
(1) does not apply for the dangerous sites authentication options code I1, N1, E4 and K6.
(2) recommend materials meet NACE MR 01-75.
code
options

B5
B6

E5
I5
K5
C6

K6(1)
I1(1)
N1(1)
E8
E4(1)
E7
I7

L4

M5
M6

Q4
J1(2)
J3(2)
T1(3)
C1
C2
C4(4)
S4(5)
P1
P2
D3
D8
Mounting bracket
2 inch pipe installation and panel installation universal mounting bracket, carbon steel bolts
2 inch pipe installation and panel installation universal mounting bracket, SST bolt
For the dangerous sites certification
Manufacturer (FM) for the absolute flame-proof certification
Manufacturer (FM) for the absolute nonflammable and intrinsically safe authentication
Manufacturer (FM) for the absolute explosion-proof and intrinsically safe authentication
Canadian standards association (CSA) explosion-proof and intrinsically safe authentication
(maximum voltage 42.4 Vdc)
CSA and CENELEC explosion-proof and intrinsically safe authentication
BASEEFA/CENELEC essence safety certification
BASEEFA N class certification
CESI/CENELEC flame-proof certification
Japanese industrial standard (JIS) flame-proof certification
The Canadian standards association (SAA) flame-proof certification
The Canadian standards association (SAA) intrinsically safe authentication
Flange and joint bolt
Austenitic 316 SST bolt
header
LCD header for aluminum shell (shell code only A, B, C)
LCD header for SST shell (shell code only J, K, L)
Other options
Check the data
Only the machine zero point adjustment
Without the machine zero point or range adjustment
Transient voltage protection terminal block
Custom software configuration (along with the contract finish CDS00806-0100-4001)
0.8 3.2 Vdc output, a digital signal based on HART protocol (only output code M)
Analog output stage in accordance with NAMUR recommended NE43, on January 18, 1994
Orifice plate and integration components connected - reference PDS00813-0100-4686 order information
Hydrostatic test
Clean, used for special applications
A quarter - 18 NPT process connection (no flange joint)
Ceramic ball drainage/exhaust valve
M (1) does not apply to low power option code.
(2) the machine zero point and range adjustment for the standard, unless specified J1 or J3 option code.
For the dangerous sites (3) shall not apply to the authentication code or I1 K6.
(4) in the factory preset is operated in accordance with NAMUR, cannot change for the standard operation at the scene.
(5) the maximum static pressure rating of the option for 3000 psi (20684 kpa), applies only to factory assembly without connected pipeline, and limited to the range of 2, 5-tetrafluorobenzoic.


上一篇: 3351 intelligent transmitter
下一篇: 3351 dp/GP type pressure transmitter
同類優(yōu)質(zhì)產(chǎn)品

在線詢價(jià)

X

已經(jīng)是會(huì)員?點(diǎn)擊這里 [登錄](méi) 直接獲取聯(lián)系方式

會(huì)員登錄

X

請(qǐng)輸入賬號(hào)

請(qǐng)輸入密碼

=

請(qǐng)輸驗(yàn)證碼

收藏該商鋪

X
該信息已收藏!
標(biāo)簽:
保存成功

(空格分隔,最多3個(gè),單個(gè)標(biāo)簽最多10個(gè)字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~