亚洲精品无码一区二区三区久久久,长春欧亚卖场是哪个区,美熟女一区二区三区,亚洲中文字幕无码一区二区三区 ,欧美人与动牲交zooz男人,日本黄h兄妹h动漫一区二区三区,亚洲国产综合久久天堂,四虎成人影视免费在线站长,小黄片午夜视频在线播放,久久久日韩精品一区二区三区

您好,歡迎來到歐亞貿易網!請 |免費注冊

產品展廳本站服務收藏該商鋪

Anhui Xin Huan Neng Electrical Co.
LTD.

免費會員
手機逛
18019898888
Anhui Xin Huan Neng Electrical Co.
LTD.
當前位置:Anhui Xin Huan Neng Electrical Co., LTD.>>Instruments and Apparatuses>>Standard instrument>> MK series intelligent pressure module

MK series intelligent pressure module

產品二維碼
參  考  價:面議
具體成交價以合同協議為準
  • 產品型號:
  • 品牌:
  • 產品類別:其他
  • 所在地:
  • 信息完整度:
  • 樣本:
  • 更新時間:2024-09-13 09:33:51
  • 瀏覽次數:7
收藏
舉報

聯系我時,請告知來自 歐亞貿易網

Anhui Xin Huan Neng Electrical Co., LTD.

其他

  • 經營模式:其他
  • 商鋪產品:431條
  • 所在地區:
  • 注冊時間:2024-09-12
  • 最近登錄:2024-09-12
  • 聯系人:manager Lu
  • 電    話:18019898888

產品簡介

CharacteristicThisexquisiteappearancestructure,strongencapsulation,goodserviceperformance

詳情介紹

Characteristic

This exquisite appearance structure, strong encapsulation, good service performance.

This unified standard for signal transmission, can be equipped with either a digital meter, pressure pick range extension.

This module built-in CPU, 24 bit A/D, temperature sensor, pressure sensor to finish continuous correction, linear, zero temperature drift, ensure accurate and reliable output signal.

Long term stability. The module (Shi Piao), the host is amended, to ensure the accuracy of the instrument for a long time.

Module selection method

* first, the customer should be clearly identified, the maximum pressure range Pmax, check the pressure gauge in the minimum pressure range Pmin, the detected meter accuracy test, delta pressure module accuracy Delta module;

* according to the standard table accuracy is tested 1/4 scale accuracy values to calculate the relationship, to choose the pressure module range covers the detected meter range ratio n; n= Delta (delta × / test module; 4);

This module follows pressure range selection:

The first module pressure range P1 required Pmax, namely, P1=Pmax. The first pressure module P1 can cover the range of the check table is P1/n;

Second pressure module range P2, should be less than P1/n of the next check table range; second pressure module P2 can cover the range of the check table is P2/n;

Third pressure module range P3, should be less than P2/n of the next check table range; third pressure module P3 can cover the range of the check table is P3/n;

Fourth pressure module range P4, should be less than P3/n of the next check table range; fourth pressure module P4 can cover the range of the check table is P4/n;

… … … …

Until the coverage of the minimum range Pmin.

For example:

There is a power plant, the plant has the following range of pressure transmitter -100kPa, 5kPa, 10kPa, 25kPa, 60kPa, 100kPa, 160kPa, 1MPa, 2MPa, 6MPa, 10MPa, 25MPa, 30MPa, 60MPa, the highest accuracy is 0.5% meters. First of all, we design the accuracy of the 1/4 with the accuracy of the meter, and then consider it from the highest range. We choose the following pressure module:

The first step in the calculation of the first, 2, =0.5% were known: Delta, delta module =0.05%, so that the pressure module range covers the detected meter range ratio n; n= Delta (delta / test module × =0.5%/; 4) (0.05%× 4) =2.5;

The second step according to the above calculation method of the third, the pressure module range is as follows:

The first module pressure range P1 60MPa required pressure module, namely, P1=60MPa. The first pressure module P1 can cover the range of the check table is P1/n=60MPa/2.5=24MPa;

Second pressure module range P2, should be less than 24MPa (P1/n=60MPa/2.5=24MPa) of the next check table range, that is, P2=10MPa; second pressure module P2 can cover the scope of the check table is P2/n=10MPa/2.5=4MPa;

Third pressure module range P3, should be less than 4MPa (P2/n=10MPa/2.5=4MPa) of the next check table range, that is, P3=2MPa; third pressure module P3 can cover the scope of the check table is P3/n=2MPa/2.5=0.8MPa;

The fourth module pressure range P4, should choose less than 0.8MPa (P3/n=2MPa/2.5=0.8MPa) of a detected meter range, i.e., P3=160kPa; range fourth P4 pressure module to cover the seized table is P4/n=160kPa/2.5=64kPa;

Fifth pressure module range P5, should be less than 64kPa (P4/n=160kPa/2.5=64kPa) of the next check table range, that is, P5=60kPa; fifth pressure module P5 can cover the scope of the check table is P5/n=60kPa/2.5=24kPa;

Sixth pressure module range P6, should be less than 24kPa (P5/n=60kPa/2.5=24kPa) of the next check table range, that is, P6=10kPa; Sixth pressure module P6 can cover the scope of the check table is P6/n=10kPa/2.5=2.4kPa;

Seventh pressure module range P7, the final choice of -100kPa, P7=-100kPa.

Refer to the above module selection method from high to low to choose the appropriate module, and then according to the needs and habits, supporting the CPC2000 series pressure calibrator.


上一篇: S304 standard digital ammeter
下一篇: Pressure pump accessories
同類優質產品

在線詢價

X

已經是會員?點擊這里 [登錄] 直接獲取聯系方式

會員登錄

X

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

X
該信息已收藏!
標簽:
保存成功

(空格分隔,最多3個,單個標簽最多10個字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時間回復您~