亚洲精品无码一区二区三区久久久,长春欧亚卖场是哪个区,美熟女一区二区三区,亚洲中文字幕无码一区二区三区 ,欧美人与动牲交zooz男人,日本黄h兄妹h动漫一区二区三区,亚洲国产综合久久天堂,四虎成人影视免费在线站长,小黄片午夜视频在线播放,久久久日韩精品一区二区三区

您好,歡迎來(lái)到歐亞貿(mào)易網(wǎng)!請(qǐng) |免費(fèi)注冊(cè)

產(chǎn)品展廳本站服務(wù)收藏該商鋪

鵬鑫(泉州)貿(mào)易有限公司

免費(fèi)會(huì)員
手機(jī)逛
15059812725
鵬鑫(泉州)貿(mào)易有限公司
當(dāng)前位置:鵬鑫(泉州)貿(mào)易有限公司>>開關(guān)>>撥動(dòng)開關(guān)>> 000507DNFT無(wú)油流量開關(guān)-LED-PS 000507

DNFT無(wú)油流量開關(guān)-LED-PS 000507

產(chǎn)品二維碼
參  考  價(jià):面議
具體成交價(jià)以合同協(xié)議為準(zhǔn)
  • 產(chǎn)品型號(hào):000507
  • 品牌:
  • 產(chǎn)品類別:撥動(dòng)開關(guān)
  • 所在地:
  • 信息完整度:
  • 樣本:
  • 更新時(shí)間:2023-07-07 16:13:47
  • 瀏覽次數(shù):11
收藏
舉報(bào)

聯(lián)系我時(shí),請(qǐng)告知來(lái)自 歐亞貿(mào)易網(wǎng)

鵬鑫(泉州)貿(mào)易有限公司

其他

  • 經(jīng)營(yíng)模式:其他
  • 商鋪產(chǎn)品:985條
  • 所在地區(qū):
  • 注冊(cè)時(shí)間:2023-07-07
  • 最近登錄:2023-07-07
  • 聯(lián)系人:蔣艷萍
  • 電    話:15059812725

產(chǎn)品簡(jiǎn)介

DNFT無(wú)油流量開關(guān)-LED-PS000507TheRevolutionaryDigitalNo-FlowTimerforCompressorLubeSystemsDNFTperformsmonitoringandshutdownfunctionslikeNo-Flow

詳情介紹

DNFT無(wú)油流量開關(guān)-LED-PS 000507

The Revolutionary Digital No-Flow Timer for Compressor Lube Systems

DNFT performs monitoring and shutdown functions like No-Flow, Low-Flow or Excessive-Flow for Divider-Block Lubrication Systems. The DNFT is a totally enclosed solid state electronic device for detecting Slow-Flow and No-Flow on in-line progressive lubrication systems. The Digital No-Flow Timer incorporates a crystal oscillator to accurately monitor the cycle time of the lubrication system enabling precision timed shutdown capability. An internal Lithium battery powers it, which is easily replaceable.


The DNFTs come in three models to switch voltages up to 240 VDC:

LED model
LCC model
PRG model


產(chǎn)品選型資料下載:

· DNFT-PRG


· DNFT-LCC
· DNFT-LED
· DNFT-LED-PS
· DNFT-PRG-PS (Programmable)
· DNFT-PRG (Standard, Programmable)
DNFT-PRG-PS (Programmable w/ PS Option)
DNFT-LCC 45 Second Alarm
DNFT-LCC 2 Minute Alarm
DNFT-LCC 3 Minute Alarm
DNFT-LCC 4 Minute 15 Second Alarm
DNFT-LED
DNFT-LED-PS


Digital No-Flow Timer (DNFT)

Premier Digital No-Flow Timer (DNFT)無(wú)油流開關(guān)產(chǎn)品介紹:

Monitors Movement of Divider Valve Piston 監(jiān)測(cè)分配器柱塞的運(yùn)動(dòng)
Closed Loop or Open Loop Operation 開式或閉式回路 Installs Directly to Divider Valve 直接安裝在分配器上面
Not Affected By Temperature or Viscosity 不受溫度和粘度的影響
Requires No External Power 不需要外接電源
LED or LCC Cycle Indicator 帶LED或LCC循環(huán)指示
Dependable “Timed" Shutdown Protection 可靠的停機(jī)保護(hù)
Explosion Proof Rated for 防爆等級(jí):
Class 1, Division 1, Groups A,B,C,D CSA Approved 通過(guò)CSA防爆認(rèn)證 CE Approved 和CE防爆認(rèn)證


SPECIFICATIONS :

Material Stainless Steel, Aluminum
Temperature Range -40 F to +185 F
Switch Rating 2.5VA/240 VDC
Epoxy Encapsulated UL LISTED EL-CAST VFR 641
Alarm/Shutdown Factory default for 2 minute alarm
Power Field Replaceable -Lithium Battery
Battery P/N 000505
Alternate Battery Radio Shack 960-0418
Divider Block Application Dropsa/Lincoln/SBCO/Lubriquip
Warranty 2.5 Years


WHITLOCK DIGITAL NO-FLOW TIMER
506LIT LED-WI-1
DNFT
WHITLOCK INSTRUMENT

07.11.01

1300 N. Texas Odessa, TX 79761
R

915.3373412 Fax 915.335.5926
DIGITAL NO-FLOW TIMER
1.800.337.3412 INSTRUMENT

U.S. PAT. NO. 5,835,372 WHITLOCK
ODESSA, TX USA
DNFT-LED
P/N: 000506

MODEL Factory Sealed RATED 2.5VA / 240VDC

R
II 2G EEx m IIB T5 CE SERIAL #
C US ClI;Zone1;ExmdIICT4 000506
ClI;Div1;Grps.A,B,C,D;T4 ALARM 2-MIN

186200 0344 P/N
KEMA 00ATEX1090 X Amb. -40° C +85°C
RED-Open Loop ORANGE-Closed Loop GRN-Ground
DNFT-LED
MONITORS MOVEMENT OF DIVIDER
VALVE PISTON FOR DEPENDABLE
"TIMED" SHUTDOWN PROTECTION

CLOSED LOOP OR OPEN LOOP OPERATION INSTALLS DIRECTLY TO DIVIDER VALVE
NOT AFFECTED BY TEMPERATUREOR OIL VISCOSITY
REQUIRES NO EXTERNAL POWER
LED INDICATOR -CYCLE INDICATION
DEDICATED SWITCH CLOSURE TO MONITOR EACH DIVIDER VALVE CYCLE (PS OPTION)
FIELD REPLACEABLE BATTERY
186200 Cl I; Div 1; Grps. A,B,C,D;T4

KEMA 00ATEX1090
X Amb.
-40° C +85°C


DESCRIPTION
The DNFT-LED is a totally enclosed electronic device, combining the latest technology in microprocessor and transistor components for detecting Slow-Flow and No-Flow of divider block lubrication systems. The DNFT incorporates an oscillating crystal to accurately monitor the cycle time of the lubrication system to enable precision timed shutdown capability. The magnet assembly and control housing mount directly to the divider valve to become an integral part of the lubrication system. The DNFT operates on a field replaceable lithium battery. If battery voltage drops below normal operating levels, the DNFT goes into alarm mode and the unit cannot be restarted. LED models utilize an LED to indicate each cycle of the divider valve. This enables the operator to easily set and monitor lubrication rates.
OPERATION
Lubricant flow through the divider valve assembly forces the pistons to cycle back and forth causing a lateral movement of a magnet linked to the piston. Movement is monitored by the microprocessor which resets the timer, lights the LED, and allows the unit to continue operation, this indicates one complete cycle of the lubrication system. The microprocessor must receive this cycle in a predetermined time or a shutdown will occur. The DNFT will automatically reset alarm circuit when normal operation of divider valve resumes.

WHITLOCK
506LIT LED-WI-2

DNFT WHITLOCK INSTRUMENT

DIGITAL NO-FLOW TIMER INSTRUMENT P/N 000506 DNFT-TO-LED DIGITAL NO-FLOW TIMER INSTALLS ON DROPSA/LINCOLN/SBCO/LUBRIQUIP DIVIDER
BLOCK. SWITCH RATING 2.5VA 240VDC

1. Loosen all Allen head set screws (A) on DNFT (B) and remove magnet housing (C). Do not remove magnet, spring or spacer from magnet housing.

2. Remove piston enclosure plug (D) from end of divider valve where DNFT will be installed. The DNFT does not have to be installed on the top divider valve. It may be installed on any convenient divider valve, top to bottom. (Notice:Do not install DNFT on Lincoln divider valves with cycle indicator pins or any Dropsa divider valve less than SMX 16.)

3. Be sure O-ring or metal gasket (F) is in place on magnet housing (C). Screw magnet housing (C) into end of divider valve (E). Torque to 15 foot pounds max.

4. Slide DNFT (B) all the way onto hex of magnet housing (C). Tighten set screws on hex of magnet housing. Torque 25 inch pounds max.

5. The LED on the DNFT indicates each divider valve cycle. This enables operator to adjust the lubricator pump for correct cycle time and oil consumption recommended by compressor manufacturer. If LED does not blink with compressor running or by manually pumping oil into divider valve, the DNFT must be adjusted. Normal cycle indication is a bright strobe type blink.

6. Before adjusting DNFT, divider valve must be cycling. This can be achieved with the compressor running or by manually pumping oil through the divider valve assembly with a hand priming pump.

7. Adjustment is made by sliding the DNFT (B) all the way on the hex of the magnet housing (C). Tighten set screws on hex of the magnet housing to 25 inch pounds max. Check for LED blink to confirm correct adjustment. If LED does not blink with divider valve cycling, adjust the DNFT back in 1/16" increments. Correct adjustment of the DNFT is confirmed by blinking LED.

8. All conduit and connections should be appropriate for area classification. Notice: Conduit and fittings must be supported to avoid bending magnet housing.

9. After installing magnet assembly and pre-compressor start-up, it is absolutely necessary to purge all air from dividerblock lubrication system. This can easily be accomplished with a lubrication system purge gun.
10.DNFT must be installed with correct magnet assembly for each divider valve manufacturer.
Lincoln-7/16"-20 extended nose with O- ring Dropsa
Trabon-1994 or earlier 7/16"-20 with metal crush gasket SBCO &Trabon-1995 and later 7/16"-20 with O-ring
Notice: When installing more than one DNFT, each DNFT must be wired to a separate alarm circuit of the control panel, annunciator or PLC to simplify troubleshooting the lubrication system and DNFT.
O-RING OR ALLEN HEAD
INTERNALVIEWOF DIVIDERVALVE METAL GASKET (F) DNFT (B) MAGNET HOUSING SPACER SET SCREWS(2) (A) SPRING #22AWG18"LEADS(7)(I)
(E) (C)
WHITLOCK
RED

DIGITALNO-FLOWTIMER
RED GREENINSTRUMENT

GREEN
ORANGE
ORANGE

CYCLEINDICATIONODESSA,TXUSA
MODEL LED
ORANGE
RATED 2.5VA / 240VDC

ORANGE
24S
Factory Sealed
R
C US
LED
CE
II2GEExmIIBT5
SERIAL#
000506

ClI;Zone1;ExmdIICT4
0344
P/N
186200
ClI;Div1;Grps.A,B,C,D;T4
2-MIN

ALARM
MAGNET FIELD REPLACEABLE
KEMA00ATEX1090XAmb.-40°C +85°C
RED-OpenLoopORANGE-ClosedLoopGRN-Ground
BATTERY
(H)
P/N:000505
DNFT-LED
O-RING
24S
PISTONENCLOSUREPLUG (F)
(D) 1/2“PIPEPLUG CONTROL HOUSING POLARIZEDCONNECTOR
CAUTION: DISCONNECT ALL WIRING PRIOR TO WELDING ON COMPRESSOR OR SKID.
WIRING LEGEND
RED NORMALLY OPEN OPERATION ORANGE NORMALLY CLOSED OPERATION GREEN CASE GROUND UNIT MUST BE SECURELY GROUNDED. DISCONNECT ALLWIRING PRIOR TO WELDING ON SKID.
CLOSED LOOP MODE

RED INSULATE CONTROL PANEL FROM CONTACT ANNUNCIATOR
OR PLC
ORANGE
ORANGE
GREEN GROUND
000506
NOTE: WIRING CONNECTION FOR UNIT IN OPERATION
DNFT-LED
000506

OPEN LOOP MODE

RED
CONTROL PANEL RED ANNUNCIATOR OR PLC
ORANGE INSULATE FROM CONTACT
GREEN GROUND
000506
NOTE: WIRING CONNECTION FOR UNIT IN OPERATION

WHITLOCK
506LIT LED-WI-3
DNFT
WHITLOCK INSTRUMENT
06.05.01


上一篇: VARTECH SYSTEMS觸摸屏VTPC170PSS11111
下一篇: PECO過(guò)濾芯FILTER C-18
同類優(yōu)質(zhì)產(chǎn)品

在線詢價(jià)

X

已經(jīng)是會(huì)員?點(diǎn)擊這里 [登錄](méi) 直接獲取聯(lián)系方式

會(huì)員登錄

X

請(qǐng)輸入賬號(hào)

請(qǐng)輸入密碼

=

請(qǐng)輸驗(yàn)證碼

收藏該商鋪

X
該信息已收藏!
標(biāo)簽:
保存成功

(空格分隔,最多3個(gè),單個(gè)標(biāo)簽最多10個(gè)字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~