亚洲精品无码一区二区三区久久久,长春欧亚卖场是哪个区,美熟女一区二区三区,亚洲中文字幕无码一区二区三区 ,欧美人与动牲交zooz男人,日本黄h兄妹h动漫一区二区三区,亚洲国产综合久久天堂,四虎成人影视免费在线站长,小黄片午夜视频在线播放,久久久日韩精品一区二区三区

您好,歡迎來到歐亞貿易網!請 |免費注冊

產品展廳本站服務收藏該商鋪

Anhui Xin Huan Neng Electrical Co.
LTD.

免費會員
手機逛
18019898888
Anhui Xin Huan Neng Electrical Co.
LTD.
當前位置:Anhui Xin Huan Neng Electrical Co., LTD.>>Instruments and Apparatuses>>Temperature sensor>> Take (FLP) thermocouple temperature transmitter/resistance

Take (FLP) thermocouple temperature transmitter/resistance

產品二維碼
參  考  價:面議
具體成交價以合同協議為準
  • 產品型號:
  • 品牌:
  • 產品類別:溫度傳感器
  • 所在地:
  • 信息完整度:
  • 樣本:
  • 更新時間:2024-09-12 13:35:46
  • 瀏覽次數:20
收藏
舉報

聯系我時,請告知來自 歐亞貿易網

Anhui Xin Huan Neng Electrical Co., LTD.

其他

  • 經營模式:其他
  • 商鋪產品:431條
  • 所在地區:
  • 注冊時間:2024-09-12
  • 最近登錄:2024-09-12
  • 聯系人:manager Lu
  • 電    話:18019898888

產品簡介

Productdescription:applicationUsuallyanddisplaymeter,recordingmeter,electroniccomputeretc

詳情介紹

Product description:


application

Usually and display meter, recording meter, electronic computer etc., 4-20 ma output, direct measurement of carbon production site of chlorine and other explosives - 200 ℃ to 1300 ℃ range of liquid, steam, gas and solid surface temperature.

The characteristics of

4-20 ma two wire output, strong anti-interference ability;
Save the compensation conductor and temperature transmitter installation cost;
Save a large range;
The cold end temperature automatic compensation, nonlinear correction circuit;

The working principle of

Thermocouple (resistance) in the working status of the change of the thermoelectric potential (resistance), after the temperature transducer of bridge produce unbalance signal, after amplification into 4-20 ma electrical signal to the instrument, the instrument will display the corresponding temperature value.
Flame-proof thermocouple (resistance) using the clearance flame-proof principle, when an explosion cavity, can remove from heat and cooling by joint clearance, the explosion flame temperature and not reach outside the cavity, thereby for temperature measurement.Thermocouple (resistance) produce thermoelectric potential (resistance) after temperature transmitter of bridge produce unbalance signal, after amplification into 4-20 ma dc signal to workers instrument, the instrument shows the corresponding temperature value.

The main technical parameters

Product standards
IEC584
IEC751
IEC1515
JB/T5518-91
JB/T7391-94

Measuring range and tolerance

1) thermal resistance temperature measurement range and tolerance

Type no.Degree,measuring℃ temperature rangefinegradeAllowable deviation
WZPBPt100- 200 - + 500
A gradeBlevel
±(0.15+0.002ItI)
±(0.30+0.005 ItI)
WZCBCu50 Cu100+ 100-50 -
±(0.30+0.005 ItI)

2) thermocouple temperature measurement range and tolerance

Type no.pointsC no.Tolerance level
III
Tolerance values℃ temperature rangeallowdifferenceTemperature measurement range
WRNBKPlus or minus 1.5 ℃- 40-375.Plus or minus 2.5 ℃- 40-333.
±0.004 ItI375-375.0.0075 ItI333-333.
WRMBNPlus or minus 1.5 ℃- 40-375.Plus or minus 2.5 ℃- 40-333.
±0.004 ItI375-375.0.0075 ItI333-333.
WREBEPlus or minus 1.5 ℃- 40-375.Plus or minus 1.5 ℃- 40-333.
±0.004 ItI375-375.0.004 ItI333-333.
WRFBJPlus or minus 1.5 ℃- 40-375.Plus or minus 1.5 ℃- 40-333.
±0.004 ItI375-375.0.004 ItI333-333.
WRCBTPlus or minus 1.5 ℃- 40-125.+ / - 1 ℃- 40-133.
±0.004 ItI125-125.0.0075 ItI133-133.

Output signals: 4-20 mA, 250, load resistance transmission conductor resistance in 100
Output method: two wire
Precision level:
Temperature transmitter precision grade: 0.1 0.2 0.5
Display precision level: analog indicating 2.5 on the Richter scale;0.5 digital display type.
Power supply: 24 v DC + 10 ℅
Protection grade: IP65
Explosion-proof level:
Flameproof: d Ⅱ BT4 d Ⅱ CT5 d Ⅱ CT6
Intrinsically safe: ia Ⅱ CT6
: insulation resistance meter output terminals between shell and insulation resistance shall be not less than 50.
Thermal response time:
When the temperature appear step change, the instrument of current output signal changes to correspond to the step change of 50% of the time required, usually with t0.5 said when the temperature transmitter does not exceed the stable step response time of thermocouple (resistance) thermal response t0.5 five points at that time, stability time with thermocouple (resistance) thermal response time as the instrument of thermal response time;When the temperature transmitter of the step stable thermal response time is less than the thermocouple (resistance) half of the time stability of thermal response t0.5, temperature transmitter thermal response time is used as the instrument of thermal response time;
The basic error:
The instrument shall not exceed the basic error thermocouple (resistance) and composite error of temperature transmitter basic error.

上一篇: SB - 3000 series thermal treasure di