亚洲精品无码一区二区三区久久久,长春欧亚卖场是哪个区,美熟女一区二区三区,亚洲中文字幕无码一区二区三区 ,欧美人与动牲交zooz男人,日本黄h兄妹h动漫一区二区三区,亚洲国产综合久久天堂,四虎成人影视免费在线站长,小黄片午夜视频在线播放,久久久日韩精品一区二区三区

您好,歡迎來到歐亞貿易網!請 |免費注冊

產品展廳本站服務收藏該商鋪

Anhui Xin Huan Neng Electrical Co.
LTD.

免費會員
手機逛
18019898888
Anhui Xin Huan Neng Electrical Co.
LTD.
當前位置:Anhui Xin Huan Neng Electrical Co., LTD.>>Instruments and Apparatuses>>Temperature transmitter>> Computed tomography (CT) temperature controller

Computed tomography (CT) temperature controller

產品二維碼
參  考  價:面議
具體成交價以合同協(xié)議為準
  • 產品型號:
  • 品牌:
  • 產品類別:溫度傳感器
  • 所在地:
  • 信息完整度:
  • 樣本:
  • 更新時間:2024-09-12 15:15:54
  • 瀏覽次數(shù):12
收藏
舉報

聯(lián)系我時,請告知來自 歐亞貿易網

Anhui Xin Huan Neng Electrical Co., LTD.

其他

  • 經營模式:其他
  • 商鋪產品:431條
  • 所在地區(qū):
  • 注冊時間:2024-09-12
  • 最近登錄:2024-09-12
  • 聯(lián)系人:manager Lu
  • 電    話:18019898888

產品簡介

Productdescription:Anoverview

詳情介紹

Product description:


An overview,
YWK -ct temperature controller adopts intelligent PID control, when measured by thermocouple, heat resistance) acquisition temperature deviation to the given value, YWK -ct temperature controller according to the deviation of measured signal with a given value of proportion (P), integral (I) and differential (D) operations, so as to control relay on-off ratio, led to a given value measurements, achieve the effect of the automatic control;The controller also has, the lower limit temperature alarm and relay output function, high cost performance, which can be widely used in electric power, chemical, plastic, packaging, food enterprises
Second, the model
YWK-CTn-K-Jn, YWK-CTn-Pt100-Jn
Third, technical indicators

Type no.
YWK-CT-K
YWK-CT-Pt100
Temperature input
K type thermocouple
Pt100 platinum resistance
Temperature measurement range
0 ~ 1300 ℃
- 20 ~ 600 ℃
Auxiliary control
J0: no alarm J1: upper limit alarm J2: the lower limit alarm J3: and the lower limit alarm
Operating temperature
Full range set freely
Alarm range
Full range set freely
The relay contact output capacity
3A/220VAC
Measurement error
Plus or minus 1% plus or minus 1 word
Working power supply
AC 220V±10%,50Hz
Power consumption
<4W
The work environment
Temperature: - 10 ~ 50 ℃ humidity: 10 ~ 90% RH (no lon)

Fourth, the dimensions and installation
YWK - CT1: appearance size: 72 mm * 72 mm * 72 mm surface mounting, hole size: 68 mm * 68 mm
YWK - CT2: overall dimensions: 48 mm * 96 mm * 96 mm surface mounting, hole size: 45 mm x 92 mm
YWK - tc3: overall dimensions: 48 mm x 48 mm x 100 mm surface mounting, hole size: 45 mm x 45 mm

Five, the panel

1, measure the temperature display screen (PV) in normal work, measured temperature value;In the parameter Settings, according to the prompt;
2, control temperature display: (SV) (set) in normal work, display control (set) temperature;When to set parameters, display each parameter values;
3, the master output indicator light: when output control relay action, indicator;When the master control relay output reduction, lights out;
4, self-tuning indicator light: when choosing self-tuning runtime, indicator;
5, the lower limit alarm indicator light: when measuring the temperature below the lower limit of set temperature, the indicator, output lower limit alarm relay action;When measuring temperature higher than the lower limit of set temperature, light, output lower limit alarm relay reset;
6, limit alarm indicator light: when the upper limit of temperature measuring temperature is higher than the set, indicator, maximum output alarm relay action;When measuring temperature is lower than the upper limit set by the temperature, light, the output upper limit alarm relay reset;
7, functional control button: hold down the key for 0.5 seconds, enter the master temperature setting state, after the master temperature setting, hold down the key for 0.5 seconds again can save Settings and exit the master temperature setting state;Press and hold the button for 5 seconds, enter a state of other parameters setting, parameter Settings, press SET button for more than five seconds, system will save Settings and exit the SET state, returned to normal;
8, set the shift key: in setting state, hold the key to choose parameters of the digital (, ten, hundred, thousand);
9, diminishing set numerical key: in setting state, press the key number minus one at a time, hold not to put the digital rapid reduction;
10, set numerical increment key: in setting state, press once the number plus one, hold not to put the Numbers quickly.
Sixth, the thermostat setting and operation
Master temperature Settings: thermostat in normal working state after the power supply, press SET key for 0.5 seconds, the red display shows the prompt "SO," green screen shows master SET temperature, at this point, the thermostat (s) into the master temperature Settings, press the shift, increasing and decreasing button can be SET or modify the control temperature.After the master temperature Settings, press SET key for 0.5 seconds again can save Settings and exit the master temperature setting state, to return to normal state.
Thermostat in normal state, press SET key for 5 seconds and the thermostat SET into the second area.At this time, each time you press the SET key, the red display will transform a prompt, green display shows the parameter values, select the shift, increasing and decreasing button to SET or modify the parameters.The