Product description:
An overview,
Transducer is a kind of alternating current (voltage) can be measured alternating current (voltage) is converted into linear proportion of output dc voltage or dc current instruments, widely used in electric power, post and telecommunications, oil, coal, metallurgy, railway, municipal departments such as electrical devices, automatic control and scheduling system.
Ac current and voltage transducer with a single road, three road combination structure, its characteristic is:
1, high accuracy (typical: 0.2% 0.05%) best.
2, the scope of the whole range has high linearity.
3, high degree of integration, simple structure, good temperature characteristic and long-term stability, the transmitter from regular check.
Second, the product name and model number
The name says | Type no. | Auxiliary power |
A single alternating current transducer | YWD-I、 YWE-I、YWF-I 、YWL-I | Optional: YWD series AC, 220 v, 110 v DC:220V 110V 48V 24V YWE, YWF, YWL series optional: DC: 24V、15V、12V |
Three combination alternating current transducer | YWD-3I、YWE-3I、YWL-3I | |
Single ac voltage transducer | YWD-U、 YWE-U、YWF-U 、YWL-U | |
Three combination ac voltage transducer | YWD-3U、YWE-3U、YWL-3U |
Vn The input voltage | V0 0~70V | V1 0~120V | V2 0~250V | V3 0~300V | V4 0~450V | V5 0~500V | V6 Set the user | ||||||||||
An Input current | A1 0~1A | A2 0~5A | A3 0~10A | A4 0~30A | A5 0~50A | Note: A4、A5、 A6、A7、 A8 Only suitable for YWF class structure of the product. | |||||||||||
A6 0~75A | A7 0~100A | A8 0~150A | A9 user-defined | ||||||||||||||
Pn Lose to the power supply | P1 DC24V±15% | P2 DC12V±15% | P3 AC220V±15% | P4 Set the user | |||||||||||||
On Lose out | O1 0~5V | O2 1~5V | O3 0~2OmA | O4 4~20mA | O5 Set the user | ||||||||||||
C) : input frequency 50 hz + / - 5 hz
D) overload input: current: 2 and 30 times in one second
Voltage: 2 times continuously
E) absorb the power: voltage loop: < 0. 5 va / 450 v
Voltage loop: < 0.2 VA / 100 v
Current loop: < 0.1 VA / 5 a
F) response time: 350 ms or less
G) : the output load current: when the auxiliary power supply 24 v or higher, RL 650 omega or less;
When the auxiliary power supply is + 12 v, + 15 v, RL 300 omega or less;
Voltage: RL 2 k or omega
H) power frequency withstand voltage: : between input/output/shell 2 kv AC/min
I) insulation resistance: 20 m or omega
J) impulse voltage: 5 kv / 1.2-50 mu s (peak value)
K) working conditions: temperature: - 10 ~ 50 ℃ humidity: 10-90% (no lon)
L) storage conditions: temperature: 10-95% - 40 ~ 70 ℃, humidity (no lon)
M) the dimensions:
YWD -i, YWD - U: 55 mm * 75 mm * 120 mm after
YWD - 3 I, YWD - 3 u: 110 mm * 75 mm * 120 mm
YWE -i, YWE - U: 42 mm * 75 mm * 75 mm
3 I, YWE YWE - - 3 u: 110 mm * 75 mm * 70 mm
YWF -i, YWF - 3: u * 31 mm * 104 mm to 77 mm
YWL -i (3 I), YWL -u (3 U) type: 75 mm * 22.5 mm * 100 mm
Five, the wiring diagram
1, YWD series single alternating current (voltage)/three combination alternating current (voltage) transmitter
< , /O:P>
2. YWE series single-phase alternating current (voltage)/three combination alternating current (voltage) transmitter
3. YWF series single-phase alternating current (voltage) transmitter
YWF-I YWF-U
4. YWL series single-phase alternating current (voltage)/three combination alternating current (voltage) transmitter
Note: 1, YWF, YWL series ac current transducer input line from the transmitter punch through the casing, regardless of polarity.
2, YWD, YWE series current transducer is only allowed by less than 10 a current, more than 10 a, can only choose YWF - type 1 product.
Six, product debugging
1, YWD, YWE single ac current and voltage transducer: find the corresponding ZERO corresponds to the transmitter panel and CAL two debugging hole, which of the two potentiometer ZERO and full adjustment potentiometer, respectively, when the calibration with a small screwdriver slowly rotate to the required accuracy.
2, YWD, YWE three combination alternating current and voltage transducer: to find corresponding to the transmitter panel ZEROA, CALA, ZEROB, CALB and ZEROC CALC six debugging hole, including the potentiometer is respectively A and B, C three way of zero and full adjustment potentiometer, calibration with A small screwdriver slowly rotate to the required accuracy.
Seven, installation,
YWD, YWE series used in a DIN rail and screw two installations, width of guide rail is 35 mm.Screw size of 12 and M3 M4 x x 12.YWF, YWL
Use DIN rail installation, guide rail width of 35 mm.
Eight, ordering instructions
When signed a procurement contract, please specify the model, specification, corresponding to the selected type in the following format to fill in, special specifications said in words
In Ming dynasty.
Case 1: YWF - I - A4 - P1 - O1
YWF - type I active single ac current transducer
Entered: AC 0 ~ 30 a
Auxiliary power supply: DC 24 v + / - 15%
Output: DC 0 ~ 5 v
Example 2: YWD - u - 3 V3 - P3 - m1
YWD - 3 u active three voltage transducer
Entered: AC 0 ~ 300 v
Auxiliary power supply: AC 220 v + / - 15%
Output: DC 4 ~ 20 ma
Nine, matters needing attention
1, input, output, auxiliary power wiring must be correct, not misplaced.
2, using the environment should be no conductive dust and no corrosive action on metals, and damage the insulation gas exists, height is less than 2500 meters above sea level.
3, switch products factory has zero and accuracy, please do not adjust.












所有評論僅代表網友意見,與本站立場無關。