亚洲精品无码一区二区三区久久久,长春欧亚卖场是哪个区,美熟女一区二区三区,亚洲中文字幕无码一区二区三区 ,欧美人与动牲交zooz男人,日本黄h兄妹h动漫一区二区三区,亚洲国产综合久久天堂,四虎成人影视免费在线站长,小黄片午夜视频在线播放,久久久日韩精品一区二区三区

您好,歡迎來到歐亞貿易網!請 |免費注冊

產品展廳本站服務收藏該商鋪

Anhui Xin Huan Neng Electrical Co.
LTD.

免費會員
手機逛
18019898888
Anhui Xin Huan Neng Electrical Co.
LTD.
當前位置:Anhui Xin Huan Neng Electrical Co., LTD.>>Instruments and Apparatuses>>SENECA Transducers>> Three-phase voltage monitor

Three-phase voltage monitor

產品二維碼
參  考  價:面議
具體成交價以合同協議為準
  • 產品型號:
  • 品牌:
  • 產品類別:其他
  • 所在地:
  • 信息完整度:
  • 樣本:
  • 更新時間:2024-09-13 08:28:03
  • 瀏覽次數:9
收藏
舉報

聯系我時,請告知來自 歐亞貿易網

Anhui Xin Huan Neng Electrical Co., LTD.

其他

  • 經營模式:其他
  • 商鋪產品:431條
  • 所在地區(qū):
  • 注冊時間:2024-09-12
  • 最近登錄:2024-09-12
  • 聯系人:manager Lu
  • 電    話:18019898888

產品簡介

Productdescription:I

詳情介紹

Product description:

I. overview

AC voltage monitor is to achieve the average measurement and display instrument of AC three-phase four wire system voltage signal phase unbalance voltage under three-phase voltage monitoring and pressure, with fast response time, high stability.

1, the main features

1) can measure the average value of three-phase voltage in real time.

2, with the phase, imbalance, overvoltage, undervoltage indication, relay output and other functions.

3, with overvoltage and undervoltage critical voltage setting function, you can achieve any critical voltage you need.

4), using LED display, intuitive and clear.

2, product model:

YWD-C3U

3, the main technical indicators

The accuracy level: 1 input voltage: 0 ~ 60V 0 ~ 110V 0 ~ 220V or user-defined output: relay contact capacity: AC:220V (380V) 7A: 10V (hysteresis voltage can be set according to user requirements): DC:15V 24V 48V 110V auxiliary power supply 220V AC:110V 220V frequency voltage: input and output, input and output power with the power supply, AC: 2kV/min.1mA: ≥ 20MΩ insulation strength of power consumption: < 40mA (DC24V) digital tube display: red (3 -) working environment: temperature: -10-50 degrees: 10-90% (without dew humidity storage conditions: temperature: -40-70 degrees humidity: 10-95% (no condensation) dimensions: 110 mm × 75 mm × 120 mm;;

Two, the working state description

The LED indicator light output contact system state description of unbalanced out off balance on closed unbalanced state (a phase voltage higher or lower than the other 20% phase voltage, can be set according to user requirements) phase out off phase closed without bright open phase state (a phase voltage is lower than 40%) arc fault overvoltage no light overvoltage overvoltage condition (closed three-phase voltage average value increased 10%) under voltage arc disconnect without undervoltage undervoltage condition on closed (three-phase voltage average value decreased by 10%)

Note: when the indicator light on the table or a few bright, the output relay normally open contact closure.

Three, operating instructions

1, undervoltage threshold voltage setting mode

Set the display / set button on the panel K1 to the set position, the overvoltage / undervoltage button K2 hits the undervoltage position, the instrument enters the undervoltage critical point voltage setting mode, and the voltage displayed by the display is the voltage at the critical point. At this point, the user can set the undervoltage threshold voltage by adjusting the voltage setting knob on the panel.

2, overvoltage threshold voltage setting mode

Set the display / set button on the panel K1 to the set position, the overvoltage / undervoltage button K2 hits the overvoltage position, the instrument enters the overvoltage critical point voltage setting mode, and the voltage displayed by the display is the overvoltage critical point voltage value. At this point, the user can set the overvoltage critical point voltage by adjusting the pressure setting knob on the panel.

3, voltage measurement mode

The display / set button on the panel K1 hit the display position, the instrument into the three-phase voltage average measurement mode, the display voltage is the average of the three-phase voltage (Va+Vb+Vc) /3.

Four, wiring and installation

1, wiring and panel

2, installation

Note: the power supply of the positive and negative polarity is not connected.

A) installation environment

1, instruments should be installed in a dry, well ventilated and away from the heat source.

2), environmental temperature: - 50 DEG c..

3, the electrical connection line with 12 ~ 14 wire.

PT (b) selection

The monitor can be directly connected to the phase voltage 346V three phase four wire system. These inputs can also be used as a secondary 220V of PT. If the system voltage exceeds 346V, the PT must be used to reduce the voltage to the 220V full scale range

PT quality directly affects the accuracy of the measurement voltage, so the PT must have a good linear and interphase relationship. The introduction of PT, if the PT rated power of more than 25W, then the secondary fuse. Under the primary excitation of PT, the PT secondary can produce lethal voltages and currents. Therefore, the installation and operation of equipment, safety precautions need to be taken (remove PT insurance)

3, installation mode

DIN guide rail and screw can be used in two ways. Screw size is M4× 12.

4, installation size (bottom view)

Five, matters needing attention

1, this instrument is only suitable for three-phase four wire system.

2, after the completion of the mode setting, switch the K1 key switch to display.

3, the use of the environment should be no conductive dust and non corrosive metal and the destruction of insulating gases exist, altitude less than 2500 meters.


上一篇: KRH humidity switch transmitter
下一篇: CT01 current transformer
同類優(yōu)質產品

在線詢價

X

已經是會員?點擊這里 [登錄] 直接獲取聯系方式

會員登錄

X

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

X
該信息已收藏!
標簽:
保存成功

(空格分隔,最多3個,單個標簽最多10個字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時間回復您~