Product description:
An overview,
Dc leakage current transducer is small dc current is realized by using magnetic modulation principle of non-contact measurement, has a good stability, high degree of insulation, installation is convenient wait for a characteristic.
Second, the technical indicators
A) model and parameters:
| Type no. | Lost in the | Lose out | Precision grade |
| YWM-LI10 | 0~±10mA | 0~±5V | 2.0 |
| YWM-LI20 | 0~±20mA | 0~±5V | 2.0 |
| YWM-LI50 | 0~±50mA | 0~±5V | 2.0 |
| YWM-LI100 | 0~±100mA | 0~±5V | 2.0 |
| YWM-LI200 | 0~±200mA | 0~±5V | 2.0 |
B) auxiliary power supply: DC + 12 v ~ + 15 v
d) The output load: RLp2kW
E) static power: 500 mw or less
F) response time: 200 ms
G) insulation withstand voltage: between the input and output, power supply AC 3000 v/min
H) hole aperture: Ф 30 mm
I) appearance size: 100 mm x 24 mm x 74 mm
J) working conditions: temperature, humidity - 10 ~ 50 ℃ : 10-90% (no lon)
j) Storage conditions: temperature: 10-95% - 40 ~ 70 ℃, humidity (no lon)
Three, installation,
usingDIN rail and screw two installations, width of guide rail is 35 mm.Screw size of M4 x 12.
Four,Which matters
1. Sensor has according to user needs to adjust well before they go out, no need to adjust.
2. Electricity for the first time, if the output is small deviation, no adjustment.aboutAfter 30 minutes output can automatically return to zero.If shut down for a long time after the reboot, want to have the above process.












所有評論僅代表網友意見,與本站立場無關。