Product description:
technical data
Output signal 4 ~ 20mA second line
0 ~ 20mA line three
Measuring range 0 ~ 100m (max)
Accuracy 0.2, 0.5
Stability is better than 0.1%/
Allow temperature medium -20 C -70 C
Environment -20 DEG C -70 C
Storage -40 DEG C -80 C
Material process connection stainless steel 1Gr18Ni9Ti
Stainless steel PTFE
Diaphragm 96% alumina
Seal fluorine rubber
Teflon
Process connection flange
install
Direct installation static pressure level transmitter, flange installation size in line with DN50 GB9119.6-88. Users can install directly.
debugging
Direct installation of static pressure level transmitter, factory zero and full range have been calibrated.
It should be noted that the full scale of the calibration is provided by the user side of the media, the calculation of the dry calibration. Due to the conditions and conditions of use is very difficult to completely consistent, so the full instructions may have different levels of access, so in the static pressure level transmitter installed after the correction of full. When the medium level correction to the maximum value, the transmitter output value correction to 20.000mA, if the conditions do not allow the medium liquid level reaches the maximum value, then according to the actual numerical level, calculate the current output value corresponding to the corrected by the formula:
Where: In level at n points when the transmitter should output current value (unit mA)
HN n point height (unit m)
Hmax measured medium maximum liquid level (ie full range, unit m)
In order to improve the accuracy of the calibration, please refer to the calibration records of the transmitter when the calibration.
Type of static pressure level transmitter
SWP code - TLD - racy sign direct mounted static liquid level transmitter transmitter type G standard D type flameproof intrinsically safe I process connection material 3 stainless steel 1Gr18Ni9Ti5 stainless steel 316L7 stainless steel coated with PTFE 9 special agreement process connection F Y special flange sealing material about sensor 1F fluorine rubber 2F nitrile rubber 3F Teflon 9F special agreement signal output 2 4-20mA 3 0-20mA three line 9 line 20.25 0.56 special agreement precision grade 1.09 special requirements range code standard range table.












所有評(píng)論僅代表網(wǎng)友意見,與本站立場無關(guān)。