Product description:
I. overview
The utility model relates to an active power transmitter and a reactive power transmitter, which is a direct current or a DC voltage which is converted into an active and reactive power output in a linear proportion. And can reflect the transmission direction of the measured power. The utility model is suitable for various single-phase, three-phase three wire and three-phase four wire systems, and can be widely used in electrical devices of petroleum, post and telecommunications, metallurgy, railway, municipal, electric power and other departments.
Two, model and size
Single phase active power transmitter model: YWD-P1
Single phase reactive power transmitter model: YWD-Q1
Single phase active and reactive power combined transmitter model: YWD-PQ1
Three phase three wire active power transmitter model: YWD-P3
Three phase three wire reactive power transmitter model: YWD-Q3
Three phase three wire active and reactive power combined transmitter model: YWD-PQ3
Three phase four wire active power transmitter model: YWD-P4
Three phase four wire reactive power transmitter model: YWD-Q4
Three phase four wire active and reactive power combined transmitter model: YWD-PQ4
Dimensions: YWD-P1 (Q1):55mm× 75mm× 120mm
The rest: 110mm× 75mm× 120mm
Three, the implementation of standards
GB/T13850-1998idtIEC688:1992
Four, the main technical indicators
A) accuracy level 0.2, level 0.5
B) input, output and auxiliary power parameters
Vn V1100VV2220VV3270VV4400V On A11AA25AA310A An input voltage output current O50 ~ 1VO60 ~ 1VO70 ~ 5VO80 ~ ± ± 5VPn; P1DC24V± 15%P2DC12V± auxiliary power supply; 10%P3AC220V± 15%P4 user O10 ~ 20mAO20 ~ 20mAO34 ~ 20mAO44 ~ ± 12 ~ 20mA
Standard input full value
Type of connection standard input full value (W/var) V1 (100V) V2 (220V) V3 (270V) V4 (400V) 1A5A1A5A1A5A1A5AYWD-P1, YWD-Q1, YWD-PQ1YWD-P3, YWD-Q3, YWD-PQ3YWD-P4, YWD-Q4, YWD-PQ4 single-phase three-phase three wire three-phase four wire 10017330050086615002004006001000200030002505008001300250040004007001200200035006000
C) overload input current: 2 times continuous for 30 times 15 seconds 100 second
Voltage: 2 times continuous
D) response time ≤ 300ms
E) power consumption: voltage loop: 0.2VA/100V
Current loop: 0.1 VA/5A
F) load capacity ≤ 650Ω
G) power frequency withstand voltage input / output / enclosure: AC2kV/min
H) impulse voltage 5kV/1.2 ~ 50μ s (peak)
I) insulation strength ≥ 100MΩ
J) working environment temperature: -10 to 50 degrees Celsius humidity: 10 ~ 90% (no condensation)
K) storage temperature: -40 ~ 70 C humidity: 10 ~ 95% (no condensation)
Five, installation
DIN guide rail and disc screw fixed in two ways, the width of the guide rail is 35mm, the screw size is M4× 12.
Six, product debugging
1, single or single active reactive power transducer: open the corresponding to the transmitter on the panel corresponding ZERO and CAL two rubber plug, the two potentiometers were zero and full scale adjustment potentiometer adjustment, with a small screwdriver to slowly rotate to the desired accuracy can be.
2, active power and reactive power combined transmitter: open the corresponding ZERO1, ZERO2, CAL1 and CAL2 four rubber plug panel corresponding to the transmitter, the four potentiometers were zero and full scale and zero reactive power and active power full adjustment potentiometer, with small adjustment screwdriver slowly rotating to the required precision.
3, the factory has been adjusted zero and precision, please do not adjust.
Seven, ordering information
Signed the contract should be specified in detail the required specifications, power and output parameters, and according to the following format code will be filled with special specifications, please use the text
Explain。
Example 1:YWD-P4-V3-A2-P1-O3
YWD-P4 type three-phase four power transmitter
Input: 270V 5A
Auxiliary power supply: DC24V± 15%
Output: 4 ~ 20mA/-4000W ~ ~ 0 ~ +4000W
Example 2:YWD-PQ3-V1-A2-P3-O8
YWD-PQ3 type three-phase three wire active and reactive power combined transmitter
Input: 100V 5A
Auxiliary power supply: AC220V± 15%
Output: 0 ~ ± 5V/0± ~ 866W (VaR)
Eight, matters needing attention:
1, the line must be shielded wire, and the power cord, the input line and the output line must be separated.
2, the use of the environment should be no conductive dust and non corrosive metal and the destruction of insulating gases exist, altitude less than 2500 meters.
3, the factory has been adjusted zero and precision, please do not adjust.












所有評論僅代表網(wǎng)友意見,與本站立場無關(guān)。